Level control for wastewater lift stations

Keep it simple with the FOGRod®

A level sensor that will never run your pumps dry, and will always start them, no matter how much grease is in the wet well.

No moving parts, sensors or electronics in the wet well. No rewiring, configuration or calibration in the panel.

How it works
Pricing & free trial
Specifications
Watch the 6-minute overview
A FOGRod hanging in a working lift station wet well, with grease and debris on the surface

FOGRod installed in a lift station, hanging from its mounting bracket.

10%

of the maintenance of floats

10-year warranty

Can't fail like pressure transducers

10× easier

than ultrasonics: no configuration or calibration

No wiring changes

Replaces floats or analog level devices

Already using the FOGRod? Manuals and tech support →

support@wastewater-level.com

How it works

The field device stays simple. The intelligence stays in the panel.

The FOGRod works by conductivity: water conducts and air doesn't. Each of its 10 metal contacts tells the panel unit whether it is under water, so the panel always knows the level in 10 steps.

The FOGRod hanging by its own cable from the supplied mounting bracket

1 · In the wet well

The FOGRod

A rod with 10 metal contacts, hanging from its own cable and a supplied bracket just under the lid. No moving parts, sensors or electronics. 3 ft, 5 ft and 7.5 ft lengths.

The LIT-100 Level Indicator Transmitter wired in a control panel, with the 10%, 20% and 30% level lights on

2 · In the control panel

The LIT

The Level Indicator Transmitter mounts on a DIN rail. It reads which contacts are under water, works around grease, and gives a Clean FOGRod alert when it needs cleaning.

10
9
8
High-level alarm
7
6
Lag pump on
5
4
Lead pump on
3
2
1
Pumps off below
Example: relays 1, 4, 6 and 8. You choose whichever relays you want.

3 · Into your existing controls

Relays and 4–20 mA

10 level relays work like floats: pick the ones you want for off, lead, lag and alarm, and wire them to the terminals the floats used. A 4–20 mA output suits transducer-style control or SCADA. Two fault relays.

Always stops the pumps

Once the level drops below the bottom contact, no current can flow through air. Any failure stops the pumps; it can't run them dry.

Always starts the pumps

Each of the 10 level points backs up the ones below it. If one contact isn't working, the pump still starts, just a little higher in the wet well.

The whole system in six minutes

The overview explains how the FOGRod and LIT work together, with more detailed explanation after the introduction.

Read the full explanation of how it works →

In the field

Built for grease, ragging and harsh wet wells

Lift station with the FOGRod coated in grease and rags, still working two months after its last clean

Two months after the last clean

The same lift station at installation, showing where the FOGRod hangs

Where it hangs, at installation

Still working, two months after the last clean

You can't tell by looking whether grease will cause a problem. The LIT detects when measurement is affected, works around it, and alarms when cleaning is needed.

Installer bolting the FOGRod mounting bracket just under a lift station hatch

Simple and quick to install

The bracket bolts into the concrete or steel just under the lid, and the FOGRod hangs from it on its own cable. See installation photos

A FOGRod in its bracket at an open lift station manhole

Clean it by pulling it up

The bracket includes a cleaning pad. Pull the FOGRod up through it and it's clean, which is much easier than cleaning floats.

Replacing something?

The FOGRod and LIT work with your existing panel logic.

Floats →

About 10% of the maintenance. The relays wire in where the floats did.

Pressure transducers →

Can't fail like a transducer. 4–20 mA output if you control on analog.

Ultrasonics →

No configuration or calibration.

Multitrode →

Alternatives to the Multitrode probe, MT2PC controller and relays.

Specifications at a glance

FOGRod lengths

3 ft, 5 ft, 7.5 ft, with contacts 3 in, 6 in or 9 in apart

Choosing a length

Match the distance from pump off to high alarm, not the depth of the well. Longer spans use two or more FOGRods (10 ft and 15 ft systems are two rods on one LIT).

Level points

10 contacts, each with its own level relay

Outputs

10 level relays, 2 fault relays, 2-wire 4–20 mA

Panel unit

LIT-100, DIN-rail mounted, front-panel level LEDs

Hazardous locations

Class I Div 2 with no barrier; Class I Div 1 and ATEX zone 0 with approved IS barriers

Approvals

UL (file E467390), C-UL, CE, RCM

Warranty

FOGRod 10 years in wastewater; LIT 2 years, extendable to 5

Stays in your panel

Pump alternation and latching come from your existing controls

Full specifications and manuals →

Pricing & free trial

List prices are published, and free trials are available.

See pricing & free trial

Questions about your station?

Call or email us about your lift station.

+1 406-545-3023
support@wastewater-level.com
Contact form →
Wastewater Level LLC is a specialist company.

Explore

Home
Why FOGRod
Tech support
Contact Us

Help

Easy installation
Pricing and Free Trial
FAQ
Specifications
About

Contact Us

Wastewater Level LLC
support@wastewater-level.com
PO Box 197, Kalispell MT 59903
406 545 3023

Copyright © 2026 Wastewater Level LLC | The FOGRod is a registered trademark of Wastewater Level LLC | Privacy Policy